Powersolve C(AC) Series Manual de usuario

Busca en linea o descarga Manual de usuario para Proveedores De Energía Powersolve C(AC) Series. Powersolve C(AC) Series User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
www.powersolve.co.uk
Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
Specification
50-22 kWatts
CE Marked LVD & EMC
1-4 Outputs
5-400 Volts Output
Eurocassette or Wall Mount
Parallel Redundant Operation
Fully Wired Customised Racks
Power Factor Correction Modules
C (AC-DC) Series
Input
DC Input Voltage See Table
AC Input Voltage See Table
Input Frequency 47-440 Hz
No-Load Input Current 3% of full load current typical
Inrush Current AC/DC limited by thermistor
DC/DC depends on impedance of supply
line, see List of Options for Option ‘I’
Earth Leakage <3.5 mA at 230 VAC, to EN60950
Output
DC Output Voltages See Table, for voltages above 250 VDC
contact Sales Office
Switch-On Time 100 ms typical C300-C4700,
500 ms typical C5600-C5800
Hold-Up Time AC/DC increases with input voltage
15 ms typical at 230 VAC
DC/DC depends on input voltage
(typical 2 ms at 12 VDC)
Line Regulation 0.1% (±10% change Vin)
Load Regulation 0.2% (10-90% load)
Transient Response 6% maximum deviation 2ms
C300-C4700, 10ms C5600-C 5800
recovery time to within 1% for load
change 20-100- 20% of full load
Ripple & Noise ≤1% +30 mV pk-pk
(0.5% typical lin. regulator auxiliary)
Overvoltage Protection Standard on single output models &
main output on multi output units
Overload Protection Current limited at 105-110% of full load
Temperature Coefficient • 0.02%/°C typical
Remote Sensing Standard for main output
1
General
Efficiency at Full Load 60-95%, depending on model
Isolation EN60950 Class 1
Switching Frequency Approx. 33 KHz
MTBF AC/DC & DC/DC approx 130,000 hrs
at +25 °C
Connector H 15 DIN 41612 or studs for higher
current outputs C300-C4700,
studs only for C5600-C5800
Environmental
Operating Temperature -20 °C to +75 °C, derate from +55 °C
at 2.5%/°C (Optional -40 °C to +75 °C)
Storage Temperature -40 °C to +85 °C
Relative Humidity 5-95%, non-condensing
EMC & Safety
RFI-Interference VDE 0878, EN 55022, Level A
Construction (Safety) EN60950 Class 1
Creepage Distance VDE 0110, 4 mm
Air Distance VDE 0110, 3 mm
High-Energy ENV 50142, Level 3
Pulses/Surges
Spike/Bursts IEC 1000-4-4, Level 3
UPS/INVERTERS
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - UPS/INVERTERS

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 2

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 3

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 4

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 5

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 6

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 7

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Pagina 8

www.powersolve.co.ukPowersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powerso

Comentarios a estos manuales

Sin comentarios