Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
Desk Top Power Supplies
PS36E Series
20-36 Watt Switch Mode
Universal AC Input
INPUT
Input Voltage Range 90 - 264Vac
Frequency 50 - 60Hz
Inrush Current 60A max. @ 240Vac
Conducted EMI CISPR/FCC Class B
Isolation - Input/Output 4242VDC
Leakage Current 0.25mA max.
OUTPUT
Hold-up Time 8mS typ. @ 115Vac
Short Circuit Protection Continuous
Over Voltage Protection Yes
ENVIRONMENTAL
Operating Temperature Range 0°C to +40°C
Storage Temperature Range -20°C to +85°C
Cooling Natural convection
GENERAL
Safety Approvals cUL/UL 60950, TUV EN60950
Dimensions 110.0 x 50.0 x 20.0 mm
4.331 x 1.969 x 0.787 inches
Weight 190g
AC Inlet IEC320/C8
Electrical Specification
Features
Universal Input Range 90-264Vac
Continuous Short Circuit Protection
Over Voltage Protection
Conductive EMI Meets CISPR/FCC Class B
CEC Level IV Compliant (Output cable length ≤1800mm)
(PS36E090: Output cable ≤1220mm)
(PS36E050: Output cable ≤1220mm, 18AWG/UL2464)
Optional Output Connectors
www.powersolve.co.uk
Output Voltage and Current Ratings
MODEL OUTPUT OUTPUT RIPPLE & VOLTAGE LINE LOAD % EFF.
VOLTAGE CURRENT NOISE SETPOINT REG. REG.
PS36E050 5V 4.0A 1% ±2% ±1% ±6% 73%
PS36E090 9V 3.0A 1% ±2% ±1% ±5% 77%
PS36E120 12V 2.5A 1% ±2% ±1% ±5% 78%
PS36E130 13.5V 2.4A 1% ±2% ±1% ±5% 80%
PS36E150 15V 2.4A 1% ±2% ±1% ±3% 80%
PS36E180 18V 2.0A 1% ±2% ±1% ±2% 81%
PS36E240 24V 1.5A 1% ±2% ±1% ±2% 81%
PS36E480 48V 0.75A 1% ±2% ±1% ±2% 83%
NOTE:
1. Voltage set point at 60% full load.
2. Output noise and ripple measured with 10µF electrolytic & 0.1µF ceramic capacitors across output at 20MHz BW.
3. Line regulation is measured from 100Vac to 240Vac at full load.
4. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% load).
Typical at 25°C, nominal line and 75% load unless otherwise stated.