Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
www.powersolve.co.uk
Lead Acid Battery Chargers
MODEL OUTPUT LOAD (CURRENT)
1
RIPPLE LINE LOAD EFFICIENCY
5
VOLTAGE
+
% MIN. RATED MAX. & NOISE
4
REGULATION
2
REGULATION
3
RP1100C-12F V1: +14.4V----- 0A 7A 8A 250mVp-p ±1% ±2% 75% Min.
RP1100C-24F V1: +28.8V----- 0A 3.5A 4A 250mVp-p ±1% ±2% 78% Min.
Note:
1. Each output can provide up to a maximum load, but total load can not exceed rated output power.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 110VAC input.
4. Ripple and Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic capacitor parallel on the test point,
at rated load and 110VAC.
5. Efficiency is measured at rated load and 110VAC input.
6. Hold-up time is measured at rated load and 110VAC input.
Charging Curve
Current
V
oltage
Fast charge
M
aintenance
7A (3.5A) I rated
V Boost 14.4V (28.8V)
V
Float 13.8V (27.6V)
1A
I
V
Dimensions are in millimeters
Dimensions: 206(L) x 136(W) x 57(H)
Colour: Blue
Material: Aluminium
34
12
24
21
18.5
5
75
5
15.5
17
126.5
15525.5 25.5
12.5 12.5
5.5
49
31.5 140.5
ON
OFF
Power
Charging Indicator
Lead Acid Battery
Automatic Switching Mode Charger