
www.powersolve.co.uk
Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England
AC-DC Converters
MHP Series
40W-100W
Features
• Compact Size - High Power Density
• Industrial & Medical Approvals
• Low Leakage Current
• Level B Conducted Emissions
• EN61000-3-2, -3 Compliant
• Convection Cooled
• Class II Approved 40-60 W Models
INPUT
Input Voltage 90-264 VAC (120-370 VDC)
Input Frequency 47-63 Hz; 440 Hz
Input Current 40 W: 0.4 A max at 230 VAC, 60 W: 0.6 A max at 230 VAC, 100 W: 0.9 A max at 230 VAC
Inrush Current 40 A max at 230 VAC
Earth Leakage Current <100
µ
A at 115 VAC, <200
µ
A at 230 VAC
Input Protection Internal 3.15 A fuse in line and neutral
OUTPUT
Output Voltage See tables
Output Voltage Trim ±5% on 3.3 V & 5 V versions, ±10% on other single output models and V1 of multi-output models.
See note 1 for MHP40/60 models
Initial Set Accuracy ±1.0% V1, ±5% V2, V3 & V4
Minimum Load See tables
Start Up Delay 2 s max
Start Up Rise Time 50 ms
Hold Up Time 16/75 ms min at 115/230 VAC
Line Regulation ±0.5%
Load Regulation ±1% single output models; ±3% V1, ±5% V2 & V3 MHP40/60 multi-output models. ±1% V1 & V2, ±5% V3 & V4 MHP100
Cross Regulation 2% on MHP40/60 only
Over/Undershoot None at turn on/off
Transient Response 4% max. deviation, recovery to within 1% in 500
µ
s for a 25% load change
Ripple & Noise 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection
1
15-135% Vnom, recycle input to reset
Overload Protection
1
10-150% on primary power limit, auto recovery
Short Circuit Protection Trip and restart (Hiccup mode)
Temperature Coefficient 0.05%/°C
GENERAL
Efficiency 80-85% depending on model
Isolation 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
Switching Frequency 70 kHz typical
Power Density 60 W: 6.25 W/In
3
, 100 W: 7.40 W/In
3
MTBF 250 kHrs per MIL-HDBK-217F
ENVIRONMENTAL
Operating Temperature 0 °C to +70 °C. Refer to derating curves for specific operating limitations.
Cooling Convection & fan cooled ratings (see derating curves)
Operating Humidity 95% RH, non-condensing
Storage Temperature -20 °C to +85 °C
Operating Altitude 3000 m
Shock 30 g pk, half sine, 6 axis
Vibration 2 g rms, 5 Hz to 500 kHz, 3 axis
EMC & SAFETY
Emissions EN60601-1-2, EN61204-3, FCC 20780, EN55022 & EN55011, level B conducted
Harmonic Currents EN61000-3-2
Voltage Flicker EN61000-3-3
ESD Immunity EN61000-4-2, level 2 Perf Criteria A
Radiated Immunity EN61000-4-3, 10 V/m Perf Criteria A
EFT/Burst EN61000-4-4, level 3 Perf Criteria A
Surge EN61000-4-5, level 3 Perf Criteria A
Conducted Immunity EN61000-4-6, 10 V Perf Criteria A
Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B
Safety Approvals EN60950, UL60950, CSA 22.2 601.1, EN60601-1, UL60601-1, CCC pending, contact sales
Electrical Specification
Comentarios a estos manuales